 {{:​mdcpickandplace:​qfnplaced.jpg|}} {{:​mdcpickandplace:​qfnplaced.jpg|}}
 +
 +===== Moisture in the air tube =====
 +
 +After not paying enough attention to the filter on my air compressor, I found a reasonable amount of moisture in the air tubes that I was worried could damage the machine internals. ​ MDC offered the following advice:
 +
 +It will not damage 7722 mechanism but followings are some tips to take care.
 +
 +  - Remove vac generator cap as shown attached photo which has urethane air filter inside (actually it is silencer) it may be wet then dry it or stay remove several days (it becomes noisy but no problem as function) Some case water goes to nozzle tip but if it is not too much just use it.
 +  - Piping to the solenoid and tape actuating pistons may contain water since they are lower position so remove black tubes from joint and blow by dry air (if you can get it).
 +  - Check aluminum manifold block of solenoid valves. There are several sealed screws so remove it and see if there is no water inside.
 +  - Wipe 2 guiding shafts to hold head by cloth and apply slight light machine oil on it. 
 +
 +{{:​mdcpickandplace:​vacgenerator.jpg|}}
 +
 +